Faults identified for repairHospitality premises with bar facilities · Derbyshire

Unexplained water use traced to washroom fittings

The meter showed continuous consumption. Testing found a faulty urinal flush control and dripping fixtures, with no concealed pipe leak indicated.

Expansion vessel, circulation pump and pipework in the hospitality premises plant room
ADI’s photograph of the plant room assessed during the investigation.

Water leak warning signs

The building had bar supplies, ice machines and multiple toilets. The meter registered about 2.5 litres a minute.

Leak detection methods used

Acoustic readings directed attention to the gents’ toilets. Supplies were isolated in stages, followed by a pressure test.

Where the water leak was found

A failed urinal flush control ran continuously. A bar tap and basin waste also needed attention.

Leak repairs and next steps

The isolated pipework held 3 bar for 45 minutes. ADI recommended repairs to the flush control and leaking fixtures; the case does not record those repairs as completed.

For your facilities team

Unexpected meter movement can come from fittings as well as hidden pipes. Check washroom controls and appliances as part of the investigation.

More commercial leak detection case studies

Arrange a commercial leak investigation

Tell the office about the building, the signs of a leak and the postcode. ADI will discuss access, any restrictions on water shut-offs, the survey cost and current availability.

0333 567 2629
  • Monday to Friday, 7:30am to 6:30pm
  • Calls reach ADI Leak Detection's office in High Wycombe. Engineers cover England, Scotland and Wales.